THE PERSONAL BREW BENCH

Identify and record your espresso machine's preinfusion phase

How to find your espresso machine's documented preinfusion phase, copy its controls and units, and log observed phase events in a brew journal tied to each shot.

5 min readBrew journal8 viewsIdentify and record your espresso machine's preinfusion phase
— · 0 votes
Contents
  1. What preinfusion means on your machine
  2. Find the definition you will record against
  3. Example: Slayer Single Group (manual V6.4, June 7, 2021)
  4. Example: Speedster (manual revised June 28, 2017)
  5. What to put in a preinfusion record
  6. A repeatable recording workflow

Preinfusion is the stage at the start of a shot when water reaches the coffee bed under a gentler, separately controlled condition before full brewing pressure arrives. How it works, what it is called and how it is set differ from machine to machine. To record it usefully, start from your machine's manual. Copy the phase label, its documented meaning and the controls and units it lists. Then log what you see during the shot in separate fields, and attach that row to the shot it belongs to.

What preinfusion means on your machine

Manufacturers deliver preinfusion in different ways. Two manuals show the range. On the Slayer Single Group, the coffee bed is wetted with flow controlled by a needle valve. On the Speedster, the coffee bed can be wetted with water at supply-line pressure while the pump is off, or through a spring-and-piston cylinder that applies pump pressure progressively. Both count as preinfusion, but the controls, cues and settings are not interchangeable. A setting copied from a forum or Reddit thread only means something if it comes from the same machine, in the same mode, using the same event definitions. Before you compare your numbers with anyone else's, confirm all three.

Find the definition you will record against

Use the manual edition that matches your machine and note its version or revision date and page numbers. Look for four things:

  • The exact name the manufacturer gives the phase, such as Pre-Brew or pre-infusion.
  • The control that governs it: lever or actuator position, timer menu, or valve.
  • The unit and range of any setting, and how the machine confirms that a setting has been saved.
  • Any cue the manual gives for when the phase should end.

Example: Slayer Single Group (manual V6.4, June 7, 2021)

The actuator has three positions. Off is at the right, Pre-Brew is in the center and Full-Brew is at the left (printed pp.20–21). In Slayer's own Slayer Shot method, flow controlled by the needle valve wets the bed during Pre-Brew. The documented cue to move left to Full-Brew is crema appearing evenly across the underside of the basket. This manufacturer cue is a different event from the first appearance of liquid, so record the two separately.

The Pre-Brew timer in the menu changes in one-second steps up to 30 seconds, and a setting of zero turns it off. Pressing the round touch sensor confirms the setting. Moving the actuator does not (printed p.24). With the timer on, moving the actuator straight to Full-Brew starts an automatic pre-brew and full-brew sequence. Note in your record whether you used this automatic sequence or controlled the phase by hand. The manual measures needle-valve flow separately, as grams of water collected per 30 seconds (printed p.22). Keep that measurement in its own field, not mixed in with the timer value.

Example: Speedster (manual revised June 28, 2017)

The lever has three positions (printed pp.11–12):
• Upper: closes the group valve and stops the pump.
• Middle: opens the valve with the pump off, letting in water at supply-line pressure for manual pre-infusion.
• Lower: opens the valve and starts the pump.
If you move the lever straight from upper to lower, a spring-and-piston progressive pre-infusion cylinder still comes into play. Once the piston reaches the end of its travel, full pump pressure is applied progressively. You can see the piston rod sticking out, which gives you a visible event to record. The Speedster's shot timer counts the whole time the group valve is open, whether or not the pump is running, so its total includes the preinfusion time.

ItemSlayer Single GroupSpeedster
Phase controlActuator in center Pre-Brew position; needle valve sets flowLever in middle position (pump off, line pressure) or progressive cylinder
Setting and unitPre-Brew timer, 1-second steps up to 30 s; 0 turns it offLever position; no timer value for the phase
Automatic optionTimer on plus a direct move to Full-BrewDirect move from upper to lower engages the progressive cylinder
Transition cue to recordCrema even across basket underside (Slayer Shot method)Piston rod reaches end of travel
Timer notePre-Brew timer is separate from the flow measurementShot timer counts all valve-open time

What to put in a preinfusion record

Give the phase its own row, linked to the main shot entry. Keep the manual's wording in separate fields from your own descriptions of what you saw.

PREINFUSION PHASE RECORD
Parent shot ID:              ____
Machine / model / version:   ____
Manual edition and page:     ____
Phase label (as printed):    ____
Documented meaning:          ____
Control used:                ____
Setting entered + unit:      ____
Mode (manual / automatic):   ____
Observed start event:        ____
Observed transition event:   ____
Beverage appearance:         ____

Illustrative example, not a real measurement: Field A is the timer value as shown on the machine's display. Field B is when liquid first appears. Field C is when you saw the phase change, such as the Slayer crema cue or the Speedster piston rod reaching the end of its travel. B and C often happen at different moments, so give each one its own entry. A programmed interval and an observed wetting event are not the same thing, and keeping them apart is what makes your records comparable.

A repeatable recording workflow

  • 1. Find the manual that applies to your machine and write down its definition of the phase, with edition and page.
  • 2. Copy only the controls and units that manual documents, and note how the machine confirms a setting.
  • 3. Choose manual or automatic mode before you pull the shot, and log it.
  • 4. During the shot, note the start event, the first liquid and the transition event in separate fields.
  • 5. Attach the phase row to its parent shot, along with your timer start and end conventions. If you record full pressure or flow curves, store them with that shot as well.
  • 6. When comparing shots, compare only records made in the same mode with the same event definitions.

Related articles