Log DiFluid R2 Extract zeroing and coffee measurement checks

Build a spreadsheet calibration record for the DiFluid R2 Extract (DFT-R102) that ties each coffee TDS reading to its reference liquid, zeroing steps, conditions and alerts.

6 min readBrew journal7 viewsLog DiFluid R2 Extract zeroing and coffee measurement checks
— · 0 votes
Contents
  1. The short answer
  2. Which device and which instructions this applies to
  3. Columns to set up in the spreadsheet
  4. Logging the zeroing step
  5. Logging each coffee reading
  6. Recording alerts and what you did next
  7. Choosing and recording a baseline convention
  8. Illustrative example: an unconfirmed zero
  9. What the log shows, and what it doesn't

The short answer

A useful calibration record for the DiFluid R2 Extract is a spreadsheet where every coffee reading sits on the same row as the zeroing that preceded it. That row names the reference liquid, the baseline convention, the steps DiFluid prescribes, the conditions at the time and the completion message or alert the device showed. Built this way in Excel, Google Sheets or any similar tool, the log lets you compare brews across sessions and see which readings rest on a confirmed zero and which do not.

This guide covers home brewing use: keeping ratios and methods repeatable and keeping personal tasting notes alongside the numbers. It follows DiFluid's own published instructions for this model. It does not rank refractometers, and it does not treat the log as proof of accuracy.

Which device and which instructions this applies to

DiFluid's Quick Startup Guide identifies the R2 Extract by model number DFT-R102. It lists a measuring range of 0–30% TDS, a resolution of 0.01% TDS and an operating temperature of 5–40°C. DiFluid publishes device-specific PDF manuals on its documents page, and a separate full guide for the R2 Extract. Put the model number and the guide you followed, including its version or file identifier and the section used, in the log header. If DiFluid later revises a step, you can then see which rows used the older procedure.

Columns to set up in the spreadsheet

Keep three kinds of information in separate columns: what the manufacturer requires, what you actually did and what the device displayed. Mixing them, for example writing "zeroed OK" when you only pressed the button, defeats the purpose of the record.

ColumnWhat to enter
Record IDA unique row label such as R-01, R-02
DeviceMake, model (DFT-R102) and serial number
Guide usedGuide name or identifier and the English section followed
Date / operatorWhen the check was done and by whom
Reference liquidThe pure water used and its source (brew water or distilled)
Baseline conventionBrew-water zero or distilled-water zero with separate baseline
TemperaturesRoom, reference, device and sample temperatures, only if you actually measured them
Dish prepCleaned and dried before reference? (Y/N)
Reference added atTime the water went into the dish
Five-second waitObserved? (Y/N)
Zeroing sequenceShort press, then press and hold until Zeroing appeared (Y/N)
Zeroing statusCompleted, attempted with completion unconfirmed, or Zero Failed
Alert / actionAny drop icon, Zero Failed or Test Error, and what you did about it
Sample IDWhich coffee the drop came from
Fresh sample?Identifier showing this was a new drop, not a re-test of the previous one
Sample cooled?Y/N
Refractive indexOnly if your display or app shows it
TDS%The displayed result
Displayed temperatureAs shown with the reading
Interval since last testAt least three seconds between continuous tests
Brew-water baseline TDS%Only for distilled-water zeroing
Corrected TDS%Calculated column (see below)
NotesBrew method, ratio, taste notes

If you want to paste the headers straight into a new sheet, this comma-separated row matches the table:

Record ID,Make,Model,Serial,Guide used,Date,Operator,Reference liquid,Reference source,Baseline convention,Room temp,Reference temp,Device temp,Sample temp,Dish cleaned and dried,Reference added at,Five-second wait,Zeroing sequence,Zeroing status,Alert,Action taken,Sample ID,Fresh sample ID,Sample cooled,Refractive index,TDS%,Displayed temp,Interval since last test (s),Brew-water baseline TDS%,Corrected TDS%,Notes

Logging the zeroing step

DiFluid recommends zeroing at the start of each session. Record the zero before any coffee reading, and fill these columns as you go through the manufacturer's English sequence:

  • 1. Clean the sample dish and make sure it is dry. Mark the dish-prep column.
  • 2. Add pure water, preferably at room temperature. Note the liquid, its source and the time you added it.
  • 3. Wait the recommended five seconds.
  • 4. Short press, then press and hold until Zeroing appears on the display.
  • 5. Watch for the completion notification and record exactly what you saw. If none appeared, say so.
  • 6. Dry the dish before adding coffee.

Logging each coffee reading

  • 1. Use clean, dry sampling equipment and let the sample cool. DiFluid's guide calls for the sample and the device to reach temperature equilibrium, and notes that hot samples can lose water to evaporation, which concentrates them.
  • 2. Add the cooled coffee to the dish and tap to test.
  • 3. Record the displayed TDS% and temperature, plus refractive index if shown. DiFluid explains that the TDS% figure is calculated from measured refractive index and temperature, which is why both conditions matter.
  • 4. Rinse the dish with clean water and wipe it completely dry before the next sample.
  • 5. Use a fresh drop for each reading. Repeatedly testing the same drop can change its concentration, so give every repeat its own fresh-sample identifier and link it back to how that sample was prepared.
  • 6. Leave at least three seconds between continuous tests and note the interval.

Recording alerts and what you did next

What the device showsWhat it means per DiFluidCorrective action to log
Drop iconThe device is requesting calibrationRun the zeroing sequence and log it as a new row
Zero FailedAbnormality during zeroingRe-clean the dish and re-zero
Test ErrorAbnormality during measurementRe-clean the dish and measure again with a fresh sample

Keep failed attempts in the sheet rather than overwriting them. A failed row followed by a corrected row shows what happened during the session. A sheet with only clean rows hides the failures.

Choosing and recording a baseline convention

DiFluid's complete guide offers two options for the reference liquid. The first is to zero with the same water you brew with, which makes that water your baseline. The second is to zero with distilled water. With distilled water, extraction work requires you to measure the brewing water separately and subtract that baseline from the coffee reading. Pick one convention, write it in every row, and don't compare readings taken under different conventions without the correction.

To turn the sheet into a simple calculator for the distilled-water case, add a formula to the Corrected TDS% column. Assuming TDS% is in column Z, the brew-water baseline in column AC and the convention in column J, a formula in Excel or Google Sheets could look like this:

=IF(J2="Distilled", Z2-AC2, Z2)

A second helper column can flag rows that should not be used for comparison until their zero is resolved:

=IF(S2="Completed", "Usable", "Check zeroing")

Illustrative example: an unconfirmed zero

This is a hypothetical example of how to record an ambiguous result, not a report of an actual test. Row R-01 records the correct device and a pure-water reference, but the operator did not see a completion notification. The honest entry for zeroing status is "attempted, completion unconfirmed". It should not be marked as passed. The operator then re-runs the sequence, sees the completion message and records that as R-02. R-01 stays in the sheet, and any coffee readings are linked to R-02.

What the log shows, and what it doesn't

A completion message tells you the zeroing procedure ran. It does not independently verify that readings are accurate. Your log can document the manufacturer's completion signal, any alerts and the preparation checks DiFluid prescribes. Only add a separate accuracy-verification column if you have actually tested against an independently specified reference with a defined acceptance procedure. For home brewing, where the goal is consistent numbers to compare against your own taste notes, a record that ties every reading to a confirmed zero and a stated baseline is usually all you need.