Log DiFluid R2 Extract zeroing and coffee measurement checks
Build a spreadsheet calibration record for the DiFluid R2 Extract (DFT-R102) that ties each coffee TDS reading to its reference liquid, zeroing steps, conditions and alerts.
Contents
- The short answer
- Which device and which instructions this applies to
- Columns to set up in the spreadsheet
- Logging the zeroing step
- Logging each coffee reading
- Recording alerts and what you did next
- Choosing and recording a baseline convention
- Illustrative example: an unconfirmed zero
- What the log shows, and what it doesn't
The short answer
A useful calibration record for the DiFluid R2 Extract is a spreadsheet where every coffee reading sits on the same row as the zeroing that preceded it. That row names the reference liquid, the baseline convention, the steps DiFluid prescribes, the conditions at the time and the completion message or alert the device showed. Built this way in Excel, Google Sheets or any similar tool, the log lets you compare brews across sessions and see which readings rest on a confirmed zero and which do not.
This guide covers home brewing use: keeping ratios and methods repeatable and keeping personal tasting notes alongside the numbers. It follows DiFluid's own published instructions for this model. It does not rank refractometers, and it does not treat the log as proof of accuracy.
Which device and which instructions this applies to
DiFluid's Quick Startup Guide identifies the R2 Extract by model number DFT-R102. It lists a measuring range of 0–30% TDS, a resolution of 0.01% TDS and an operating temperature of 5–40°C. DiFluid publishes device-specific PDF manuals on its documents page, and a separate full guide for the R2 Extract. Put the model number and the guide you followed, including its version or file identifier and the section used, in the log header. If DiFluid later revises a step, you can then see which rows used the older procedure.
Columns to set up in the spreadsheet
Keep three kinds of information in separate columns: what the manufacturer requires, what you actually did and what the device displayed. Mixing them, for example writing "zeroed OK" when you only pressed the button, defeats the purpose of the record.
| Column | What to enter |
| Record ID | A unique row label such as R-01, R-02 |
| Device | Make, model (DFT-R102) and serial number |
| Guide used | Guide name or identifier and the English section followed |
| Date / operator | When the check was done and by whom |
| Reference liquid | The pure water used and its source (brew water or distilled) |
| Baseline convention | Brew-water zero or distilled-water zero with separate baseline |
| Temperatures | Room, reference, device and sample temperatures, only if you actually measured them |
| Dish prep | Cleaned and dried before reference? (Y/N) |
| Reference added at | Time the water went into the dish |
| Five-second wait | Observed? (Y/N) |
| Zeroing sequence | Short press, then press and hold until Zeroing appeared (Y/N) |
| Zeroing status | Completed, attempted with completion unconfirmed, or Zero Failed |
| Alert / action | Any drop icon, Zero Failed or Test Error, and what you did about it |
| Sample ID | Which coffee the drop came from |
| Fresh sample? | Identifier showing this was a new drop, not a re-test of the previous one |
| Sample cooled? | Y/N |
| Refractive index | Only if your display or app shows it |
| TDS% | The displayed result |
| Displayed temperature | As shown with the reading |
| Interval since last test | At least three seconds between continuous tests |
| Brew-water baseline TDS% | Only for distilled-water zeroing |
| Corrected TDS% | Calculated column (see below) |
| Notes | Brew method, ratio, taste notes |
If you want to paste the headers straight into a new sheet, this comma-separated row matches the table:
Record ID,Make,Model,Serial,Guide used,Date,Operator,Reference liquid,Reference source,Baseline convention,Room temp,Reference temp,Device temp,Sample temp,Dish cleaned and dried,Reference added at,Five-second wait,Zeroing sequence,Zeroing status,Alert,Action taken,Sample ID,Fresh sample ID,Sample cooled,Refractive index,TDS%,Displayed temp,Interval since last test (s),Brew-water baseline TDS%,Corrected TDS%,Notes
Logging the zeroing step
DiFluid recommends zeroing at the start of each session. Record the zero before any coffee reading, and fill these columns as you go through the manufacturer's English sequence:
- 1. Clean the sample dish and make sure it is dry. Mark the dish-prep column.
- 2. Add pure water, preferably at room temperature. Note the liquid, its source and the time you added it.
- 3. Wait the recommended five seconds.
- 4. Short press, then press and hold until Zeroing appears on the display.
- 5. Watch for the completion notification and record exactly what you saw. If none appeared, say so.
- 6. Dry the dish before adding coffee.
Logging each coffee reading
- 1. Use clean, dry sampling equipment and let the sample cool. DiFluid's guide calls for the sample and the device to reach temperature equilibrium, and notes that hot samples can lose water to evaporation, which concentrates them.
- 2. Add the cooled coffee to the dish and tap to test.
- 3. Record the displayed TDS% and temperature, plus refractive index if shown. DiFluid explains that the TDS% figure is calculated from measured refractive index and temperature, which is why both conditions matter.
- 4. Rinse the dish with clean water and wipe it completely dry before the next sample.
- 5. Use a fresh drop for each reading. Repeatedly testing the same drop can change its concentration, so give every repeat its own fresh-sample identifier and link it back to how that sample was prepared.
- 6. Leave at least three seconds between continuous tests and note the interval.
Recording alerts and what you did next
| What the device shows | What it means per DiFluid | Corrective action to log |
| Drop icon | The device is requesting calibration | Run the zeroing sequence and log it as a new row |
| Zero Failed | Abnormality during zeroing | Re-clean the dish and re-zero |
| Test Error | Abnormality during measurement | Re-clean the dish and measure again with a fresh sample |
Keep failed attempts in the sheet rather than overwriting them. A failed row followed by a corrected row shows what happened during the session. A sheet with only clean rows hides the failures.
Choosing and recording a baseline convention
DiFluid's complete guide offers two options for the reference liquid. The first is to zero with the same water you brew with, which makes that water your baseline. The second is to zero with distilled water. With distilled water, extraction work requires you to measure the brewing water separately and subtract that baseline from the coffee reading. Pick one convention, write it in every row, and don't compare readings taken under different conventions without the correction.
To turn the sheet into a simple calculator for the distilled-water case, add a formula to the Corrected TDS% column. Assuming TDS% is in column Z, the brew-water baseline in column AC and the convention in column J, a formula in Excel or Google Sheets could look like this:
=IF(J2="Distilled", Z2-AC2, Z2)
A second helper column can flag rows that should not be used for comparison until their zero is resolved:
=IF(S2="Completed", "Usable", "Check zeroing")
Illustrative example: an unconfirmed zero
This is a hypothetical example of how to record an ambiguous result, not a report of an actual test. Row R-01 records the correct device and a pure-water reference, but the operator did not see a completion notification. The honest entry for zeroing status is "attempted, completion unconfirmed". It should not be marked as passed. The operator then re-runs the sequence, sees the completion message and records that as R-02. R-01 stays in the sheet, and any coffee readings are linked to R-02.
What the log shows, and what it doesn't
A completion message tells you the zeroing procedure ran. It does not independently verify that readings are accurate. Your log can document the manufacturer's completion signal, any alerts and the preparation checks DiFluid prescribes. Only add a separate accuracy-verification column if you have actually tested against an independently specified reference with a defined acceptance procedure. For home brewing, where the goal is consistent numbers to compare against your own taste notes, a record that ties every reading to a confirmed zero and a stated baseline is usually all you need.
Related articles
Record a Bruer cold-drip brew from setup to beverage yield
A practical log for a Bruer cold-drip session: method check, Bruer's setup quantities, drip-rate counting, timing events, collected beverage and cleanup notes.
Organize Existing Coffee Equipment Around Your Brewing Workflow
Set up a DIY home coffee station using only what you own: map your brewing sequence, group tools by use, check placement, and record a repeatable routine.
Keep a personal tasting record as one coffee brew cools
A practical guide to recording successive tasting notes from a single coffee brew as it cools, using elapsed time, measured temperatures and clear comparisons.
Identify and record your espresso machine's preinfusion phase
How to find your espresso machine's documented preinfusion phase, copy its controls and units, and log observed phase events in a brew journal tied to each shot.
Interpret and record espresso pressure readings in context
Looking for the optimal bar pressure for espresso? Learn what your gauge actually measures, how to tell a setting from a reading, and how to log pressure so your numbers can be compared.
Record espresso basket dimensions, dose ratings and headspace
58mm espresso baskets share a diameter but differ in depth and dose range. How to record basket specs, actual doses and headspace checks without guessing at fit.
Record espresso pressure and flow profiles as separate observations
Build a stage-by-stage espresso profile record that keeps intended settings, measured pressure, measured flow and inferred curve segments apart.
Record a Nel Drip Recipe, Pouring Sequence and Beverage Yield
Build a cloth-filter brewing journal that keeps the author's nel drip method intact, logs each pour and pause as it happens, and records beverage yield as its own measurement.
Build a model-specific percolator brewing journal
Record your percolator's model, instructions, heat source, brewing events and completion cues so you can repeat a stovetop or electric routine and compare recipes fairly.
Document espresso spraying and uneven flow before changing preparation
Build a repeatable espresso observation record that separates what you saw, like spraying or uneven flow, from what you suspect caused it and what you change next.